Bosch Solution 2000/3000 can support 2 x B308 Output Expansion Modules.
Please set the Address Switch of B308 as below:
First B308:
Second B308:
If you want to use the outputs on B308 for RSC+ app control, please set the Event Code for the Outputs to "Remote Control".
Please use below Event Code for RSC+ app control:

Let's take the first Output on B308 to control the Garage Door as an example.
B308 Output 1 | ||
Item | Location | Data |
Event Code | 0646 | 2 |
Event Code | 0647 | 8 |
Polarity | 0648 | 3 |
Time Base | 0649 | 2 |
Time Base Multiplier | 0650 | 0 |
Time Base Multiplier | 0651 | 1 |
You will see "Output 1" on your RSC+ app then you can click on "Output 1" then Turn on/off your Garage Door.