Solution 64 - Prox Reader Open a Door only (no Arm/Disarm)

Modified on Wed, 13 Jun, 2018 at 10:59 AM

The CM110 Relay Output Module allows 2 separate PR100 Prox Readers to be connected to the Solution-64 Control Panel.

Up to 3 x CM110 modules can be fitted to the Solution 64 panels running Version 1.10 firmware or higher.


Solution 64 can support up to 6 water resistant external Prox Readers.




Example: use Prox Reader 9 to open a Door:


1) MENU 162 to assign Prox Reader 9 Access Group 1 to 8, e.g, Access Group 1;

2) MENU 411 to assign a spare Output Event Type 60 - Access group;

    MENU 412 to assign Event Assignment - 001 Access Group 1;

    MENU 413 to assign Output Polarity - 04 Normally Open 1 Shot Low;

    MENU 414 to assign Time Parameter - 10 seconds;

3) MENU 120 to add tokens for Prox Reader 9;

4) MENU 145 to assign Access Group for the token users - Access Group 1;

5) MENU 161 to change Prox Reader 9 area to 0;

6) MENU 163 to untick "All On Arming Allowed" and "Disarming Allowed" for Prox Reader 9;

7) Present token to Prox Reader 9 to access door.



Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article