Scenario:


Customer has a DOOR that gets unlocked when they initially disarm the system to gain access.

They want the system to UNLOCK this door at 9am  Mon  to Fri

They want the system to LOCK this door at 5pm Mon to Fri


They do not wish to have to set up HOLIDAYS to operate.


They want the door to lock if the system was armed at any time during the day.

They want the door to NOT unlock on the Schedule if the system is NOT DISARMED.


Solution.


1) Set-up the Door


Menu 420 - we can give the DOOR a NAME (Default = Door 1 Name  for DOOR 1)


Menu 612 -Turn OFF Part Arming Allowed (Default =Y)

Menu 613 - Give Reader an AREA ( default = A1)

Menu 614 - Turn ON Reader Area Control (Default = Y)  Turn ON Reader Badging ( Default = N)

Menu 617  - Assign a DOOR to the READER  (Default = NO DOOR)   ONLY a single door can assigned


2) Set-up the Users


Each User MUST be assigned to the DOOR  (Menu 145 - default = NO DOORS)

Each User must be allocated a TOKEN  (Menu 120   ADD TOKEN)


3) Set up the TIME ZONE to keep the door unlocked


Menu 750   Give Time zone a NAME

Menu 751  Select a time to START and STOP the operation (  We have an ability to set-up 4 different time periods if necessary)  Set-up for PERIOD 1 

Menu 752  Select the DAYS we want this to operate ( M T W T F ) 


4) Set-up the OUTPUT that is controlling the DOOR


Menu 411 - Event type = 60  DOOR

Menu 412 - Event Assignment = (this will be the DOOR NUMBER)  for example DOOR 1

Menu 413 - Output Polarity =  this is how the output will SWITCH when the reader is badged)   This will be (OPEN 1 shot LOW) for a Door Strike or LOW -1 shot OPEN for a MAG LOCK.

Menu 414 - TIMEFRAME = this is how long the output will operate for when the door is triggered. (commonly 10 secs)


Menu 422  Door UNLOCK Timezone  this is where we set the TIME ZONE we created to UNLOCK the door during the day

Menu 423  Door Options:  We must activate  HOLD OFF IF AREA ARMED  (default = Y)   this means if the system is ARMED , the OUTPUT to unlock the door between 0900 and 1700 would not operate and the door stays locked.