By default, when the alarm is triggered in STAY Arming mode, the Siren and Strobe will go off. Some installers may want to turn this feature off. Please follow the instructions below:


On IUI-SOL-ICON codepad:

 

(1) Enter programming mode;

(2) Type in [4][9][8] followed by [AWAY] or [#];

(3) Type in [1] followed by [STAY] or [*];

(4) Type in [9][6][0] followed by [AWAY] or [#] to exist from programming mode.


On IUI-SOL-TEXT / IUI-SOL-TS5 / IUI-SOL-TS7 codepad:


(1) Enter programming mode;

(2) Type in [3][6][6];

(3) Follow the screen prompt to set this function OFF;

(4) press the [–] button till it asks you to “Confirm to Save Parameter Changes?”  press [#] for YES.