Solution 2000/3000 - Firmware Version 2.1


What's new?


Silent codepad alarms

In previous versions of the firmware, the codepad Panic / Fire / Medical alarm only can be programmed as silent in the Location 493.

The firmware now supports to switch the codepad Panic / Fire / Medical alarm on or off in the Location 404.

 

Codepad alarm when siren is on

In previous versions of the firmware, the codepad does not give an audio indication when the system is in alarm.

The firmware now supports the codepad buzzer which gives an audible alarm indication when the siren is on.

 

Programmable System-wide tamper condition

The firmware now supports to program the hardware tamper condition as Off, Silent, Audible or Trouble.

 

System-wide tamper (hardware tamper) includes:

– onboard tamper

– module tamper

– enclosure tamper

– codepad tamper, which can be individually enabled / disabled

 

Service mode

The control panel now supports service mode to help installers with onsite support.

You can configure the service mode via codepads or via A-Link Plus.

Options for report, output, and codepad buzzer can be enabled or disabled in service mode.

 

View cloud status on IUI-SOL-ICON codepad

In addition to the alphanumeric codepad IUI-SOL-TEXT, now the installers or Master Code

users can inquire cloud status with the ICON codepad IUI-SOL-ICON.

Cloud status can be displayed on codepad indicator LED1 or LED2 corresponding to

communicator 1 or 2.

– Steady on - cloud online

– Flash - cloud offline

 

Diagnose RF devices on IUI-SOL-ICON codepad

In addition to the alphanumeric codepad IUI-SOL-TEXT, now the installers or Master Code users can check the RF strength of the RF devices (RF Zone / RF Keyfob / RF Repeater) with the ICON codepad IUI-SOL-ICON.

 

Revise triggering method for codepad alarms

In previous versions of the firmware, a "press and release" method was used to trigger Panic Alarm / Fire Alarm/ Medical Alarm on codepads.

In addition to the "press and release" method, now the "press and hold" method also trigger the Panic Alarm / Fire Alarm/ Medical Alarm.

 

Change zone type for Zone 8 to "Instant"

Change the default value of zone type for Zone 8 from 24 Hour Tamper to Instant to avoid the system to go into unexpected alarm.

 

Assign User 32 with Quick Arm function

In previous versions of the firmware, the User 8 was treated as the last one from available users; now it is corrected to grant the User 32 as the last user, and Quick Arm function is moved from User 8 to User 32 accordingly.

 

Change RF supervision time to 12 hours

Change the default value of RF supervision time (only for Solution 3000) from 0 to 12 hours.

 

APP updates

Remote Security Control Plus (RSC+) app allows you to control your security systems remotely from mobile devices such as phones and tablets.

 

The RSC+ app compatible for control panel firmware version 2.1 is updated with more user friendly operations and UI:

– Zones configured for two areas can be displayed in two areas

– Configurable push notification sound (iOS only)

– Display the custom naming in history events that is configured in the system by A-Link Plus or alphanumeric codepad IUI-SOL-TEXT

– Batch commands for reduced connection times

– Compatible for larger screen sizes

– IPv6 implementation


Manuals for all features attached