Add additional Codepads to Bosch Solution 2000/3000

Modified on Wed, 17 Feb, 2021 at 12:01 PM

By default, only codepad 1 is switched on. 


If you want to add additional Codepads, you will need to check the DIP switch settings for IUI-SOL-ICON or IUI-SOL-TEXT to make sure your codepads will be recognised.


 

For IUI-SOL-TS5 and IUI-SOL-TS7 codepads, you will need to go to Settings -> Advanced Settings -> Change Address to set the address.


Once the Address settings have been changed you will need to assign the codepads to the relevant areas. 


By default Codepad 1 is allocated to Area 1.


Example,


If you have 1 Area and 2 codepads, on IUI-SOL-ICON codepad, the programming will be:


 

Location 518 = 1 (Codepad assigned to Area 1)

Location 519 = 1 (Codepad assigned to Area 1)


On IUI-SOL-TEXT / IUI-SOL-TS5 / IUI-SOL-TS7, the programming will be:



MENU 51, then use the Down Arrow button to highlight "Codepad 2" followed by [#], then use the Down Arrow button to highlight "1 - Area 1" followed by [#].


Was this article helpful?

That’s Great!

Thank you for your feedback

Sorry! We couldn't be helpful

Thank you for your feedback

Let us know how can we improve this article!

Select at least one of the reasons
CAPTCHA verification is required.

Feedback sent

We appreciate your effort and will try to fix the article