Setup a DIVAR IP2000 back to Factory Default using the DOM to rebuild the unit.
Preparation
Connect the VGA monitor (5) and network (2) (avoid IP address conflict)
Connect the USB keyboard and mouse to the USB ports (3). Use the 2 USB ports under the Network port only for this step.
The DOM’ing process
Boot (startup) the system
You have several options to get into the DOM. When you see the Bosch Logo startup, press the <F7> key.
The other keys <DEL> and <F2> will get into the Bios setup menu. Please do not use these unless you need to modify settings.
Initial to Factory Image – Top level will wipe all Operating System (OS) and Video data. Restore to Factory Image – Wipes the OS, but keeps the video data. Note: For this process to be able to recover the system with video data intact, you must be able to reload the saved Config of the unit. Reboot – As it states, reboots the unit and allows the system to back to its normal system, or after an Initial Factory Setup will bring the unit back to its original out of the box state. |
Normally to rebuild the system it is recommended to:
Initial to Factory Image
Reboot.
Depending on system configuration, this may take from 15-45 minutes.
After Reboot, the unit will take you through to the Normal Windows start-up screen where you will see
CTRL – Alt – Del.
After this stage, the unit may be set up depending upon requirements and version of DIVAR IP 2000.
The initial release of these units will be normally added to Configuration Manager, and its client software, Bosch Video Client (BVC).
R2 (Revision 2) of these boxes were normally to be set up using a Browser. The IP Helper tool would be used to do the initial discovery and IP address assignments.