Setup a DIVAR IP7000 back to Factory Default using the DOM to rebuild the unit.
Preparation
If possible, save the existing BVMS configuration to USB media using Configuration Wizard or Configuration Client.
From Configuration Client, go to System | Export Configuration. Ensure you save the configuration to your USB stick then remove the stick till required later on.
Adding the Configuration file back in is the same, except you choose Import Configuration.
Connect a keyboard, mouse, DVI monitor (2) and network (1) (avoid IP address conflict)
Do not use the VGA, even during normal Windows usage as it is not meant to support high-level graphics required for CCTV systems.
The DOM’ing process
Boot (startup) the system
When you see the Bosch Logo startup, press the F11 key.
This will bring you into a menu that gives you options for booting into other bootable devices.
Choose “SATA:4M-ATP Velocity MI SATA DOM”
Initial Factory Setup – Top level will wipe all Operating System (OS) and Video data. System Recovery – Wipes the OS, but keeps the video data. Note: For this process to be able to recover the system with video data intact, you must be able to reload the saved Config of the unit. Wipe Disks – Will clean all disks and all data will be wiped. Recommended doing this prior to doing an Initial Factory Setup. Reboot – As it states, reboots the unit and allows the system to back to its normal system, or after an Initial Factory Setup will bring the unit back to its original out of the box state. Other items mentioned are not required for DOM rebuild. |
Normally to rebuild the system it is recommended to:
Wipe Disks
Initial Factory Setup
Reboot.
Alternatively, it may be sufficient, and quicker to:
Initial Factory Setup
Reboot.
Depending on system configuration, this may take from 15-45 minutes.
After Reboot, the unit will take you through the Initial Deployment phase, where you will be required to:
Choose your language
Select Regional Settings, i.e. Region, Time & Keyboard Layout.
Check the boxes for accepting the Eula License Agreement
After another short period, you will come up to the login screen where you will be required to put in the default password for the BVRAdmin account (main Windows Administrator account), which is WSS4Bosch.
Youtube Video: