1. Open Config Client

2. Click on Devices Tab

3. Look and expand for VRM Devices

4. Expand the VRM IP Address

5. Right click on Pool(0)

6. Click on Add iSCSI device

7. Fill out the information needed. The Username and Password will be the DIP 6000 windows username and password

8. Click Save

9. Right click on the DIP 6000 name or IP Address

10. Select Scan Target

11. Expand the DIP 6000

12. Click on 0 and it will give the LUNs details on the right side. Make sure that all LUNs are 100% Formatted. If not, put a checkmark on all LUNs and then click Format LUNs

13. Click Save and Activate once done


If you get a popup saying "Scanning for Targets and LUN's failed" you will need to check the Megaraid storage manager to see if the Raid 5 setup has been completed.

If the Megaraid storage manager is showing the drives you will have to perform a system recovery using the DVD and select option 1 initial factory image. 

Once booted back into windows you can follow the steps above.